DVS-G · PRECISION UNDER PRESSURE

Digital Vacuum Gauge for Vacuum Bagging & Resin Infusion

See small vacuum changes clearly before resin flows. The DVS-G gives composite manufacturing teams a high-resolution numerical reading for bag checks, vacuum drop testing and process verification.

0.1 inHgV resolution   /   Rechargeable   /   High-visibility LED

DVS-G portable digital vacuum gauge with bright LED display

VACUUM MEASUREMENT

What is a digital vacuum gauge?

A digital vacuum gauge measures pressure below the surrounding atmosphere and presents the reading as a numerical value. In vacuum bagging and resin infusion, it helps an operator observe vacuum level, check stability and record changes during a defined test.

The DVS-G displays vacuum in inches of mercury vacuum (inHgV). As the vacuum deepens, the displayed inHgV value increases. The reading describes conditions at the measurement point; gauge placement, restrictions and long hose runs can affect how well that point represents the bag.

When comparing digital vacuum gauges, match the measurement units, range, accuracy, connection and documentation to your process. The DVS-G is presented here for composite process monitoring; an inHgV reading should not be treated as a micron-scale absolute-pressure measurement.

DVS-G DIGITAL VACUUM GAUGE
Digital Vacuum Systems DVS-G portable digital vacuum gauge
0.1 inHgV Resolution
±0.075 inHg Accuracy
29.6 inHgV Full Scale

PORTABLE DIGITAL VACUUM GAUGE

See the vacuum. Not the estimate.

The DVS-G gives composite manufacturing teams a clear, high-resolution digital view of vacuum level so subtle changes are easier to detect during bag checks, vacuum drop tests and production verification.

DESIGNED FOR PRODUCTION

Built for resin infusion, vacuum bagging and other composite manufacturing environments where process integrity directly affects finished-part quality.

DVS-G TECHNICAL OVERVIEW PRODUCTION READY
Measurement Range
0.0 to 29.6 inHgV
Display Resolution
0.1 inHgV
Stated Accuracy
±0.075 inHg
Process Connection
1/4 in NPT
Display
High-Visibility LED
Power
Rechargeable
01
Easier Leak Detection

High-resolution digital readings make small vacuum changes easier to identify than estimating between analog dial markings.

02
Built for the Shop Floor

Rugged construction, bright display and rechargeable operation support everyday production use.

03
Useful Beyond the Bag

Sensitive enough to help evaluate vacuum lines, fittings, gauges and other parts of the vacuum system.

INTERPRETING THE SPECIFICATIONS

Resolution, accuracy and the vacuum reference

0.1 inHgV display resolution

The display changes in tenths of an inch of mercury vacuum. Resolution is the visible increment; it is separate from the stated accuracy of ±0.075 inHg.

29.6 inHgV range/reference

The published DVS-G range is 0.0 to 29.6 inHgV, and the site uses 29.6 inHgV as a full-vacuum reference. Actual attainable readings depend on local atmospheric pressure, altitude and system conditions. This is not a universal acceptance target.

Confirm your process requirements

Discuss required accuracy conditions, verification or calibration documentation, connection compatibility and operating conditions when requesting a quote. Use the requirements in your controlling procedure to select the instrument.

INSTRUMENT SELECTION

Digital vs. analog vacuum gauges

Analog gauges show vacuum with a needle against a printed scale. A digital vacuum gauge presents a numerical reading, reducing the need to estimate between dial markings. That can help operators compare beginning and ending values during timed tests.

Practical differences when selecting a vacuum gauge
ConsiderationDigitalAnalog
ReadingNumerical value; DVS-G has a high-visibility LEDNeedle position on a graduated dial
Small changesVisible as changes in the displayed incrementDepend on dial spacing, scale and viewing angle
RecordingOperators can manually record the displayed numberOperators estimate and record needle position
SelectionMatch accuracy, range and verification requirements to the process; display technology alone does not establish suitability.

Digital monitoring does not improve the vacuum source by itself. Analog indication may be adequate for broad tolerances or a validated procedure. Read the full digital vs. analog comparison →

COMPOSITE PROCESS APPLICATIONS

From bag checks to leak troubleshooting

Vacuum bagging

Use a digital vacuum gauge for vacuum bagging to observe evacuation and stability at the selected measurement point. Place the gauge so the reading is meaningful for the bag and follow the approved process.

Resin infusion

A vacuum gauge for resin infusion supports pre-infusion bag checks and monitoring. Confirm vacuum integrity before introducing resin, using your process-defined acceptance criteria and measurement arrangement.

Vacuum drop testing

Evacuate, allow stabilization, isolate as required by the procedure, then record starting and ending values over the specified interval. The DVS-G helps make small displayed changes visible. Read the drop-test guide →

Leak troubleshooting

Use readings as feedback while checking bag seals, fittings, lines and connections. Vacuum drift can also reflect material outgassing, temperature or stabilization; a changing reading alone does not locate or prove a leak. Explore leak troubleshooting →

On larger parts, consider measurement location and multiple points where required. Review gauge placement guidance →

QUALITY & TRACEABILITY

Documentation that supports your purchasing requirements

DVS-G records can connect critical component serial numbers, final assembly verification and completed functional testing to the finished gauge. Discuss Certificate of Conformance, serial-number traceability and any calibration documentation requirements with DVS before ordering.

A Certificate of Conformance and final functional verification serve different purposes from calibration documentation. Confirm which records are available and suitable for your quality system; do not infer accredited calibration or a particular certification from traceability alone.

For aerospace, defense and other controlled manufacturing work, the customer’s drawing, specification, approved procedure and quality requirements govern instrument acceptance and use. Application descriptions do not establish approval for a specific aircraft, platform or program.

Explore component traceability →   Review final functional verification →

SELECT ORGANIZATIONS SERVED

Experience across demanding aerospace and composite environments.

DVS products have been supplied to organizations working in aerospace, defense, engineering research and advanced composite manufacturing.

USC Viterbi School of Engineering
Shield Aviation Inc.
Sekisui Aerospace
Quatro Composites
Northrop Grumman
General Atomics Aeronautical
AIM Aerospace

Company and organization names and marks are shown for factual identification only and do not imply endorsement, certification, approval or affiliation.

DVS-G PRICING & APPLICATION SUPPORT

Specify your next digital vacuum gauge.

Tell us your quantity, vacuum process, connection needs and documentation requirements. DVS can review your application and provide purchasing information.